Toner & drum help HL-L9200CDW: recognize new TN339 toner A touchscreen HL procedure for this US catalog family.
1 min read Use only after fitting new toner Use this supplier counter procedure only after fitting a new, full, compatible toner cartridge and checking that it is seated correctly. Resetting an empty or partly used cartridge will not refill it. Leave the existing drum counter unchanged.
Confirm the replaced color 1 While the front cover is closed, note where the Down arrow appears when navigating a normal menu. Return to the main screen.2 Open the front cover and hold that same, now hidden, Down-arrow position for about five seconds.3 Choose the replaced color’s HC toner entry, then confirm Yes. This guide is for the new high-yield TN339 cartridge.4 Close the front cover. If the reset menu does not appear, stop and contact us. Stop if the controls differ Stop if your exact model, controls or reset menu do not match these instructions. Send us the model, cartridge label and displayed message rather than trying another printer’s button sequence.