Toner & drum help Brother DCP-L2510D/MFC-L2710DW: two-line LCD toner reset Use Clear and Stop/Exit, then the up arrow to confirm the selected toner capacity.
1 min read The listed models use physical Clear and Stop/Exit keys with a two-line LCD. Do not use the Back+Go sequence from the single-line HL printer.
Use only after replacing the toner Fit a new, full, compatible toner cartridge before using this procedure. Resetting an empty or partly used cartridge will not refill it and will make its recorded life misleading. Keep the existing drum counter unchanged.
Check the local model and toner Models covered: DCP-L2510D, DCP-L2530DW, MFC-L2710DW. Use the STD toner entry for TN-2410 or HC for TN-2420. The entry may include a K prefix for black.
Reset after fitting the new toner 1 With the printer on and the new toner fitted, open the front cover.2 Hold Clear and Stop/Exit together for one to two seconds. Release both and immediately press Clear again.3 Use the arrows to choose the installed toner capacity: the STD entry for standard toner or HC entry for high-yield toner. Press OK.4 At Reset/Exit, press the up arrow. When Accepted appears, close the front cover. If the menu or message differs Stop if the listed controls or toner entry are missing. Close the cover and send Ink Hero your exact model, cartridge number and a photo of the message. A counter reset cannot repair a faulty chip or make the wrong cartridge compatible.
Help with a toner reset Technical references